Scanning electron microscopes (SEM)

Topic

The model describes the operation of a scanning electron microscope from electron acceleration, its focus on the sample, and the generation of signals used to form images and analyze the elementary composition. It relates the electronic energy, the optics of the instrument, the interaction with the material and the acquisition. It allows to study the resolution, depth of field and signal strength. The kinetic energy of the beam depends on the charge of the electron and the applied acceleration voltage. From that energy, De Broglie's ratio determines a wavelength inversely proportional to the square root of the product of electronic mass and energy. Greater acceleration reduces the wavelength and modifies the ideal resolution limit. The model also estimates the speed of the electron from its kinetic energy and its mass by means of a non-relativistic approach, applicable only to sufficiently low energies. The spatial resolution is approximated by the Rayleigh criterion, which relates the electronic wavelength to the numerical aperture of the system. The depth of field also depends on both magnitudes, but it varies inversely with the square of the numerical aperture. This reveals the commitment between detail and focused region. The actual formation of the probe is represented by the effective diameter of the beam, calculated as a quadratic combination of the source diameter and the contribution of the aberrations. Thus, the practical resolution does not depend only on the wavelength. As you hit the sample, the primary beam causes the emission of secondary electrons. The intensity of this signal is expressed as a function of the beam current, the emission performance of the material, the considered thickness and the mean free path of the secondary electrons. The exponential dependence represents a progressive saturation of the contribution of thickness. The signal relates excitation and properties of the sample to the image. Energy dispersion X-ray microanalysis (EDX) is incorporated by a ratio between the detected accounts, the electronic current, the acquisition time and the concentration of the analyzed element. This links spectrum, measurement and composition. The beam sweep is described by the image area and its acquisition frequency, to characterize the scan. These expressions are simplified formulations: EDX ratio and sweep speed require dimensional review, while ideal optical resolution and non-relativistic speed have limited validity areas. Together, the model offers a basis for evaluating compromises between acceleration energy, focus, contrast, elementary analysis and measurement time, subject to experimental validation.

ID:5305

gphysics.net - Dr. Willy H. Gerber © 2026