The aseptic packaging lines fill sterile products (UHT milk, juices, soups) in previously sterilized containers under clean room conditions with overpressure of sterile air, without allowing recontamination. The physical model integrates microbial kinetic, thermodynamics and sealing mechanical. The inactivation of microorganisms follows a first-order kinetics: the population decreases exponentially with the treatment time, with a constant K that depends on the temperature according to the Arrhenius equation. The value F0 is the integral of the lethal effect accumulated along the process temperature profile, normalized to 121.1 C with the most resistant microorganism (Clostridium botulinum, z = 10 K); The FDA requires a minimum of 3 minutes for commercial sterility, although values of 6-15 are typical for safety margin. The sterilization of the container is carried out with hydrogen peroxide in the gaseous or liquid phase; The effective dose depends on the concentration and contact time according to the Chick-Watson model. The thermal sealing of the packaging material (polyethylene, multilayer aluminum) is carried out by partial melting of the interface under pressure and temperature controlled; The sealing pressure determines the weld's tightness and mechanical strength. The speed of the line in containers per second is the production capacity parameter that defines the investment and return of the asset. The expected behavior is that the F0 grows exponentially with temperature, which allows to reduce UHT process times (2-5 sec to 140 C), better preserving the organoleptic quality than the classic autoclave sterilization (20 min a 121 c).