Separation of Liquid Mixtures. The distillation and rectification towers of the chemical industry separate mixtures of solvents, chemical intermediates and reaction products by difference of volatility. The physical model is the VLE (vapor-liquid balance): in each plate or filling section, the vapor and liquid are balanced by exchanging components according to the relative alpha volatility. For ideal mixtures, the equilibrium curve y = f(x) follows the simplified Raoult formula; For real mixtures with molecular interactions, activity models (Wilson, NRTL, Uniquac) are used. McCabe-Thiele's graphic method builds the lines of operation of rectification and exhaustion on the y-x diagram to graphically count the theoretical dishes. The minimum number of dishes is calculated algebraically by the Fenske equation at total reflux. The optimal reflux ratio of operation (typically 1.2 to 1.5 times the minimum) balances the cost of capital (number of dishes) with the energy cost (reboiler vapor). The reboiler is the largest consumer of energy: its load is proportional to (R+1)*D*DeltAHV, growing almost linearly with reflux. In fill columns, the HetP (Height Equivalent Theoretical Plate) measures the efficiency of the fill: lower heights indicate greater mass transfer efficiency. The column's flood velocity, calculated by the Fair-Souders-Brown correlation, sets the upper operating limit: if the vapor exceeds that speed, it drags the liquid up and the column loses the separation. The expected behavior is that the reflux ratio and the steam conversion are the control variables; The column pressure determines the operating temperatures and the energy consumption of the reboiler.