The gas turbine operates according to the Brayton cycle: ambient air enters the high pressure ratio axial compressor (15-25:1), is heated in the combustion chamber with natural gas or burning, and the hot gases expand in the Turbine producing mechanical work. In the open cycle, the exhaust gases (750-900 K) are poured into the atmosphere; In a combined cycle, these gases heat the recovery boiler (HRSG) to generate steam that moves an additional steam turbine. The efficiency of the ideal Brayton cycle grows with the compression ratio according to the formula (1 - 1/Rc^((Gamma-1)/Gamma)): the higher the rc, the higher the efficiency, but the work of the compressor also grows. The inlet temperature to the gas turbine (TIT, turbine inlet temperature) is the most influential parameter in efficiency and power: modern H-Class turbines operate at 1700 C TIT with blade cooling. The combined cycle achieves efficiencies of 55-65% by harnessing the exhaust heat of the gas turbine in a steam turbine: the efficiency of the combined cycle is the efficiency of the gas turbine plus the efficiency of the steam turbine applied to residual heat. The exhaust temperature of the gas turbine is the outlet temperature of the expansion to atmospheric pressure according to the isentropic ratio. The expected behavior is that the efficiency of the actual Brayton cycle is less than the ideal one due to the irreversibilities of the compressor (typical 85-90%) and the turbine (88-92%); The ambient temperature directly affects the power and efficiency because the intake air density and temperature changes.